Search results for "Laser frequency"

showing 4 items of 4 documents

Electromagnetically Induced Transparency and optical pumping processes formed in Cs sub-micron thin cell

2012

Abstract The Electromagnetically Induced Transparency (EIT) effect in a Λ -system formed by Cs atoms (6 S 1/2  − 6 P 3/2  − 6 S 1/2 ) confined in an extremely thin cell (ETC) (atomic column thickness L varies in the range of 800 nm –3 µm is studied both experimentally and theoretically. It is demonstrated that when the coupling laser frequency is in exact resonance with the corresponding atomic transition, the EIT resonance parameters weakly depend on L , which allows us to detect the effect at L  =  λ  = 852 nm. EIT process reveals a striking peculiarity in case of the coupling laser detuned by Δ from the atomic transition, namely the width of the EIT resonance rapidly increases upon an in…

Materials science[ PHYS.QPHY ] Physics [physics]/Quantum Physics [quant-ph]Electromagnetically induced transparencyDephasingPhysics::OpticsSub-micron cell01 natural scienceslaw.inventionCaesium vapor010309 opticsOptical pumpingOptics[PHYS.QPHY]Physics [physics]/Quantum Physics [quant-ph]law0103 physical sciencesPhysics::Atomic PhysicsElectrical and Electronic EngineeringPhysical and Theoretical Chemistry010306 general physicsExact resonancebusiness.industryResonanceLaserAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsVelocity selective optical pumping resonancesLaser frequencyAtomic physicsbusinessCoherence (physics)Electromagnetically Induced Transparency
researchProduct

Numerical 2D And 3D Simulations of a Spherical Fabry–Pérot Resonator for Application as a Reference Cavity for Laser Frequency Stabilisation

2015

Abstract We report on the results of a numerical study of deformations of a spherical Fabry-Pérot cavity that can be used for laser frequency stabilisation. It is demonstrated that for a precise simulation of the cavity deformations a 3D model has to be used instead of a simpler 2D model, which employs simulation on the symmetry plane of the cavity. To lower the sensitivity to environmental perturbations, it is suggested to use a material with a low density and a high Young’s modulus. We also show that the mechanical resonance frequencies of the cavity are mainly determined by the size of the cavity.

Materials sciencebusiness.industryPhysicsQC1-999General Engineeringlaser frequency stabilisationPhysics::OpticsGeneral Physics and AstronomyReference cavityfabry-pérot cavityResonatorOpticsnumerical simulations.Physics::Accelerator PhysicsLaser frequencybusinessFabry–Pérot interferometerLatvian Journal of Physics and Technical Sciences
researchProduct

Note: Simultaneous modulation transfer spectroscopy on transitions of multiple atomic species for compact laser frequency reference modules

2018

We present a technique for simultaneous laser frequency stabilization on transitions of multiple atomic species with a single optical setup. The method is based on modulation transfer spectroscopy, and the signals are separated by modulating at different frequencies and electronically filtered. As a proof of concept, we demonstrate simultaneous spectroscopy of the potassium D1, D2 and rubidium D2 transitions. The technique can be extended in principle to other atomic species given the availability of optics and cells and allows the development of versatile and compact frequency reference modules.

Materials sciencebusiness.industrychemistry.chemical_elementAtomic species01 natural sciencesRubidium010309 opticsModulation transferchemistryProof of concept0103 physical sciencesOptoelectronicsPhysics::Atomic PhysicsLaser frequency010306 general physicsbusinessSpectroscopyInstrumentationReview of Scientific Instruments
researchProduct

An evaluation procedure for scanning interferometer based wavemeters

2004

Abstract A common approach to wavelength measurement is the travelling interferometer (wavemeter). We present an evaluation procedure that allows to achieve high precision with a compact device. The zero crossings of the interference signal corresponding to the reference laser is used to sample the signal of the probe laser. Electronic noise and fluctuations of the laser frequency cancel due to the large number of sample points. The evaluation procedure has been applied to a wavemeter based on a continuously moving Mach–Zehnder interferometer. A travelling path of 10 cm was sufficient to yield 3σ-accuracy of Δ λ / λ =3.2×10 −9 , demonstrated by comparison with cesium saturation spectroscopy.

PhysicsSignal processingbusiness.industryInterference (wave propagation)LaserAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionInterferometryWavelengthOpticslawElectrical and Electronic EngineeringPhysical and Theoretical ChemistryLaser frequencySpectroscopybusinessSaturation (magnetic)Optics Communications
researchProduct